FL-XT  FLame eXTinguish

Rapid
Early-Stage
Fire Suppression For Electrical Enclosures,
including Distribution
Panels and MCCs.

graph

CAUSES OF FIRES IN KOREA (2025)

graph

[Source: National Fire Data Center]

Real-World Customer Test Footage (Door Open) - FL-XT

FL-XT: Automatic suppression for rapid early-stage fire knockdown.

Product Information

FL-XT Series(Compact Enclosure Fire Suppression Device)

Compact fire suppression device that automatically detects and extinguishes fires in small, confined spaces

Extinguishing agent discharge port

Fully sealed container design

Lightweight, compact design for installation in cabinet-type switchboards and control panels.

Heat-triggered activation (glass bulb)

Halogenated Extinguishing Agent

소공간 소화용구

Installation Target

  • MCC control panels for continuously operating equipment (ventilation, exhaust, drainage) in underground facilities.
  • Inverters and connection panels for solar installations where limited maintenance access increases fire risk.
  • Switchboards, electrical and control panels, server rooms, server racks, and conveyors used on production lines.
  • Switchboards and HVAC outdoor units in high-heat, fire-prone areas such as traditional markets (dense vendor stalls).

For electrical enclosures at risk of overheating fires—DB/SB/CP/MPP, MCC, UPS, Telecom Cab., Battery Cab., INV/CONV, ESS Cab.—and HVAC ODU. Ideal for enclosed/semi-enclosed spacesto contain fire spread.

각종 캐비닛 이미지

Features

  • Semi-permanent lifespan

    Semi-permanent Service Life

  • US PATENT

    US PATENT

  • Made in Korea Precision hand-finished

    Made in Korea Precision hand-finished

  • Temp. detection for all models

    Temp. detection for all models

  • KC Mark KFI Type Approval

    KC Mark KFI Type Approval

  • K-Mark certified

    K-Mark certified

  • Rapid response in 1–3 seconds

    Rapid response in 1–3 seconds

  • Automatic discharge

    Automatic discharge

  • Simple installation

    Simple installation

  • Simple installation

    Multi Option (monitoring system)

Proven performance and
track record over 6 years since launch.

Spec.Small

Installation Method :
Flexible top mounting

KTL Certification : PB12021-016

  • FL-XT 360 FL-XT 120 FL-XT 40

FL-XT 40
Equipment Categories Fire Extinguishing Equipment for Small Spaces
Fire Test Model 300 × 200 × 700
KFI Design Protected Volume(㎥) 0.03
K-Mark Protected Volume(㎥) 0.04
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent
FL-XT 120
Equipment Categories Fire Extinguishing Equipment for Small Spaces
Fire Test Model 400 × 300 × 1000
KFI Design Protected Volume(㎥) 0.089
K-Mark Protected Volume(㎥) 0.12
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent
FL-XT 360
Equipment Categories Fire Extinguishing Equipment for Small Spaces
Fire Test Model 600 × 500 × 1200
KFI Design Protected Volume(㎥) 0.26
K-Mark Protected Volume(㎥) 0.36
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent

Spec.Medium

Installation Method :
Vertically on the top side

  • FL-XT 3000 FL-XT 1200 FL-XT 360G

FL-XT 360G
Equipment Categories Automatic Gas Fire Extinguishing System
Fire Test Model 600 × 600 × 1,000
KFI Design Protected Volume(㎥) 0.36
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent
FL-XT 1200
Equipment Categories Automatic Gas Fire Extinguishing System
Fire Test Model 900 × 900 × 1,500
KFI Design Protected Volume(㎥) 1.215
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent
FL-XT 3000
Equipment Categories Automatic Gas Fire Extinguishing System
Fire Test Model 1,200 x 1,200 x 2,000
KFI Design Protected Volume(㎥) 2.88
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent

Spec.Large

Installation Method :
Vertically on the top side

  • FL-XT 6000 FL-XT 10000

FL-XT 6000
Equipment Categories Automatic Gas Fire Extinguishing System
Fire Test Model 1,500 x 1,500 x 2,500
KFI Design Protected Volume(㎥) 5.625
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent
FL-XT 10000
Equipment Categories Automatic Gas Fire Extinguishing System
Fire Test Model 1,800 x 1,800 x 3,000
KFI Design Protected Volume(㎥) 9.72
Fire Detection Glass Bulb
Activation temperature 68℃
Ambient Activation temperature -20~50℃
Service Life Semi-permanent

Examples of Protected Volume

Small unit: cm
FL-XT 40 FL-XT 120 FL-XT 360
Protective
Coverage

0.04m³
Protective
Coverage

0.12m³
Protective
Coverage

0.36m³
Medium unit: cm
FL-XT 1200 FL-XT 3000
Protective
Coverage

1.215m³
Protective
Coverage

2.880m³
Large unit: cm
FL-XT 6000 FL-XT 10000
Protective
Coverage

5.625m³
Protective
Coverage

9.72m³

Monitoring system for FL-XT

The FL-XT automatic fire suppression system provides real-time monitoring of fire events and system anomalies. If an irregularity is detected, it immediately sends alerts through the dashboard and notification channels (SMS, email, WhatsApp, Messenger).

  • 소화/이상현상 알람 Fire/abnormality Alerts Messenger/email/etc.
  • 소화/이상현상 알람 Dashboard Real-time monitoring
  • 소화/이상현상 알람 Alerts / Trans logs Anomaly logs
  • 소화/이상현상 알람 Custom Map Location display
    (optional)
  • 소화/이상현상 알람 Integration with
    ERP and
    groupware systems
  • 소화/이상현상 알람 API provided Customized
    service
  • 소화/이상현상 알람 Equipment
    management
    Reg., mod.,

Monitoring systemProcess

Fire occurs in a small enclosure FL-XT automatic fire suppression device operation
모니터링 시스템 작동
Monitoring system is activated
(detects & logs the event)
  • Alert
    generated
  • Alert delivered
    (SMS, email)
  • HQ monitoring team
    initiates response

Photos of Installation Process

  • Before
  • During
  • After
  • Before
  • During
  • After

Installation Cases

Air Conditioner's Condensing Units




당진 문예의전당 화재 진화 사례

Fire Suppression at Dangjin Cultural Center

Certification and Patent Status


U.S. Patent Certificate


  •  

Authorized Dealer Information

For Product Inquiries